Fujitsu BS2000 Manual de instrucciones - Página 11
Navegue en línea o descargue pdf Manual de instrucciones para Servidor Fujitsu BS2000. Fujitsu BS2000 30 páginas. Server unit x86
Server Unit SU300
2.2.1 Controls
ID
RST
NMI
U41860-J-Z126-1-76
Identification (ID) button
The ID indicators light up (blue) on the front and on the rear of the Server Unit
when the ID button is pressed. The two ID indicators are synchronized.
On/Off switch
When the Server Unit is switched off, it is switched on again by pressing the
On/Off switch once.
When the Server Unit is in operation, it is switched off by pressing the On/Off
switch once (this takes a little time).
Normally the system may only be switched on or off by Customer Support.
The customer should only perform an "emergency power off", see SE300
"Switching off in an emergency" in the Basic Operating Manual [1].
For information on switching on and starting the SE300 and on switching it off
and shutting it down, see "Switching the SE300 on/off" in the Basic Operating
Manual [1].
V
CAUTION!
Loss of data
When the On/Off switch is pressed and held down for several
seconds, Server Unit operation is terminated ungracefully and
abruptly. Notify Customer Support.
I
The On/Off switch does not disconnect the server from the voltage
grid. To disconnect from the voltage grid completely, remove the
power plug(s).
Reset button
Pressing the Reset button reboots the Server Unit.
V
CAUTION!
Possible loss of data!
NMI button
V
CAUTION!
Do not press! Possible loss of data! The NMI button may only be used
by Customer Support.
Front of the Server Unit
11