Fujitsu PRIMEQUEST 3800E Manual de configuración del sistema - Página 18

Navegue en línea o descargue pdf Manual de configuración del sistema para Servidor Fujitsu PRIMEQUEST 3800E. Fujitsu PRIMEQUEST 3800E 38 páginas.

Fujitsu PRIMEQUEST 3800E Manual de configuración del sistema
FUJITSU Server PRIMEQUEST 3800E
Power Supply Unit (PSU)
PSU#0
PSU#1
PSU#2
SB #0
SB #1
CPU
CPU
Memory
Memory
x12 slots
x12 slots
I/O Unit #0
I/O Unit
#1
PCI Slots
x4
LAN
port
Disk Unit #0
HDD/SSD
RAID
Card
FBU
Disk
Disk Unit_M #0
Unit_M
#1
HDD/SSD
RAID
Card
FBU
PSU_M
MMB #0
MMB #1
AC Power
input
CPU (W)
>=200
=<165
240V
>=200
=<165
*1: At least 3 PSUs and 1 PSU_M are required. No installation restriction of components.
4 PSUs and 2 PSU_Ms configuration is resistant to failure of one power supply unit. Dual power feed is not possible.
*2: At least 2 PSUs and 1 PSU_M are required. The maximum number of I/O unit is 2.
3 PSUs and 2 PSU_Ms configuration is resistant to failure of one power supply unit.
*3: At least 2 PSUs and 1 PSU_M are required. The maximum number of I/O unit is 2.
4 PSUs and 2 PSU_Ms configuration is dual power feed configuration.
Dual power feed configuration is resistant to one data center power feed failure and PSU failure.
If the number of IOU or PCIe SSD exceed the above limit in the PSU 2 + n configuration (*2, *3),
it is necessary to check the power consumption of the configuration.
For request of configuration check, please submit request to the contact shown below
PSU#3
SB #3
SB #2
I/O Unit
I/O Unit
#3
#2
1x PSU_M is included for Disk/MMB Unit.
Disk Unit #1
Max 2x PSU_M can be mounted.
Disk
Disk
Unit_M
Unit_M
#2
#3
PSU_M
#0
#1
# of components
DIMM
PCIeSSD
IOU
8
4
96 slots
8
4
(Max.
2
2
12TB)
2
2
2x Normal PSU is included in Base Unit.
Max 4x PSU can be mounted.
200V Normal PSU
MC-5HPS71 / MCX5HPS71 (LD)
- 2x Nomal PSU is included in the Base unit.
- Max. 4x PSU can be mounted for PSU redundancy.
- 80PLUS® Platinum certified
200V Normal PSU for Disk/MMB Unit
MC-5HPS91 / MCX5HPS91 (LD)
- 1x PSU_M is included for Disk/MMB Unit.
- Max. 2x PSU_M can be mounted for PSU redundancy.
- 80PLUS® Platinum certified
Power Cords
# of PSUs
PSU
3 + 1 (*1)
3 + 1 (*1)
2 + 1 (*2) / 2 + 2 (*3)
2 + 1 (*2) / 2 + 2 (*3)
18 of 38
System Configuration Guide
Dual
Power feed
PSU_M
1 + 1 (*1)
No
1 + 1 (*1)
No
1 + 1 (*2, *3)
Yes
1 + 1 (*2, *3)
Yes