Fujitsu PRIMERGY TX150 S6 Manual del suplemento de servicio - Página 26

Navegue en línea o descargue pdf Manual del suplemento de servicio para Servidor Fujitsu PRIMERGY TX150 S6. Fujitsu PRIMERGY TX150 S6 45 páginas.
También para Fujitsu PRIMERGY TX150 S6: Notas sobre el uso (8 páginas)

Fujitsu PRIMERGY TX150 S6 Manual del suplemento de servicio

Replacing the IDTEMP combo

Replacement routines
4.7
Replacing the IDTEMP combo
This board includes two important system components:
– EEPROM for the chassis ID and ident number of the server
– temperature sensor for monitoring the environment temperature
The current temperature values and EEPROM data are transmitted to the
2
system board via the connected I
C bus.
The IDTEMP combo must be correctly installed in order:
– to monitor the temperature correctly,
– to enable the server management to display the correct system picture,
– to install the server using ServerStart.
The IDTEMP combo is situated on a separate holder under the hard disk cage.
Ê Open the server as described in the
section "Preparation" on page
17.
Figure 8: Removing the holder
Ê Push the holder inward from the front side.
Ê Take out the holder carefully.
2
Ê Remove the green cable clamp from the connector of the I
C cable.
2
Ê Remove the I
C cable from the connector on the IDTEMP combo.
26
Service Supplement
TX150 S6