Table of burner and nozzle specifications

Table 1
Burner
Diameter
(mm)
Rapid (Large)
100
(UR)
Semi-rapid
75
(Medium) (S)
Auxiliary
55
(Small) (A)
Supply
pressure
Maximised (mbar)
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
****
Natural P.C.S. = 37.78 MJ/m³
Pressed petroleum gas (LPG)
Nominal (mbar)
Required
Minimum (mbar)
pressure
Maximum (mbar)
S
S
UR
A
K6G40S / T
K6G40S / T
K6G40S / T
K6G40S / T
K6G40S / T
S S S
KN6G40SA / T
KN6G40SA / T
KN6G40SA / T
KN6G40SA / T
KN6G40SA / T
S S S
WARNING! The glass lid can break
in if it is heated up. Turn off all the
burners and the electric plates be-
fore closing the lid.
Thermal power
Bypass
kW (p.c.s.*)
1/100
(mm)
Nominal
Reduced
3.30
0.70
41
1.90
0.40
30
1.00
0.40
30
Nominal (mbar)
Minimal (mbar)
Natural
Gas
37 **
28 ***
20 ****
25 **
20 * **
17 ****
45 **
35 ***
25 ****
ø 180
S
UR
A
K6M40S/ T
K6M40S/ T
K6M40S/ T
K6M40S/ T
K6M40S/ T
S S S
KN6M40SA/T
KN6M40SA/T
KN6M40SA/T
KN6M40SA/T
KN6M40SA/T
S S S
Liquid gas
Nozzle
Capacity*
Nozzle
1/100
g/h
(mm)
***
**
91
240
236
70
138
136
50
73
71
28-30
37
20
25
35
45
TECHNICAL DATA
Oven dimensions
32x43,5x40 cm
(LxDxH)
62 l
Volume
Useful
width 42 cm
measurements
depth 46 cm
relating to the oven
height 8,5 cm
compartment
Power supply
see data plate
voltage and
frequency
may be adapted for use with any type of
Burners
gas shown on the data plate
Directive 2002/40/EC on the label of
electric ovens. Standard EN 50304
ENERGY LABEL
Energy consumption for Forced
convection – heating mode:
Oven;
EC Directives: 06/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments –
04/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
0051
0051
0051
subsequent amendments –
0051
0051
93/68/EEC dated 22/07/93 and
subsequent amendments –
2002/96/EC.
1275/2008 Stand-by/ Off mode
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
Natural gas
Capacity*
1/100
l/h
(mm)
123
314
106
181
79
95
20
17
25
Fan
19
GB