Kohler BodySpa K-1000 Manual de instrucciones de instalación - Página 18

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Sanitarios Kohler BodySpa K-1000. Kohler BodySpa K-1000 28 páginas. Tower custom hydro-massage system
También para Kohler BodySpa K-1000: Manual del propietario (48 páginas)

Kohler BodySpa K-1000 Manual de instrucciones de instalación
N. ADJUST THE STOP BLOCKS
TE:
NO
This step is critical to prevent the side door panels
from accidentally slamming against one another.
With the doors all closed, open the left side door. Slide the
loose stop block up against the exposed center door roller.
Close the left side door so it rests against the side jamb
seal. Slowly open the right side door until it nearly touches
the left side door. A 1/4" gap between the side door panel
edges is sufficient.
Open the left side door to expose the stop block. Carefully
secure the stop block in place by tightening the stop block
setscrew.
Repeat this procedure for the other stop block.
O. APPLY SEALANT
Door seals are an integral part of this door. However,
sealing with a quality clear silicone sealant is necessary
to ensure a properly functioning, watertight unit.
The required sealing procedure follows:
Mask both edges of joint to be sealed, maintaining a
joint width of 1/8" to 3/16".
Apply a uniform bead of sealant. Smooth the bead with
your finger.
Remove the tape from the sealed joints immediately
after smoothing the bead.
Repeat for all areas to be sealed.
Very Important! Apply silicone sealant to the outside
bottom edge of the center jambs and wall jambs only. On
the inside, apply a bead of silicone sealant vertically along
the seam between the wall jambs and finished wall
surface. Do not apply sealant to the inside bottom of the
center jambs and wall jambs.
IMPORTANT! You have now completed the door enclosure installation phase
of the BodySpa installation. Keep these instructions with the tower so they are
readily available for the final installation procedures.
AB
116290-2-
Stop Block
Stop Block
Setscrew
INSIDE UNIT
Footbath
18
Inside
Header
Track
Roller
Center Door Panel
Apply
Sealant
1/8" to 3/16"
Joint Width
Center
Jamb
Masking Tape
Apply
Sealant
Kohler Co., Kohler WI U.S.A.
Wall
Jamb