Kohler BodySpa K-1000 Manual de instrucciones de instalación - Página 8

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Sanitarios Kohler BodySpa K-1000. Kohler BodySpa K-1000 28 páginas. Tower custom hydro-massage system
También para Kohler BodySpa K-1000: Manual del propietario (48 páginas)

Kohler BodySpa K-1000 Manual de instrucciones de instalación
B. INSTALL CABLE USING OUTLET BOX
NOTE: If the desired keypad location does not permit you
to secure the provided outlet box directly to a stud, you can
route the control cable directly through the wall material
without using an outlet box. Proceed to Step C. to install
the keypad without an outlet box.
Plug the control cable into the right jack of the control box.
Position the supplied outlet box inside the enclosure at the
chosen control mounting location so the metal plate (not
shown) will be flush with the finished wall or slightly
recessed when installed. Install the outlet box so the 10'
control cable is within reach of the control box. Do not
stretch or pull on the control cable. Install the outlet box
58" to 60" up from the floor of the footbath.
Secure the outlet box to the nearest stud.
Route the control cable from the control box to the outlet
box, and insert the loose connector into the knockout hole
in the outlet box. Create a drip loop in the cable.
TE:
NO
National Electrical Code requires that you
permanently separate the high- and low-voltage cables.
C. INSTALL CABLE WITHOUT OUTLET BOX
Plug the control cable into the right jack of the control box.
Route the control cable directly through the large hole in
the center of the metal plate. Temporarily tape together
the control cable and the metal plate. Also tape the two
screws to the metal plate to prevent them from becoming
lost. Create a drip loop in the cable to prevent water from
following the cable down to the control box.
Temporarily secure the control cable and metal plate to
the stud nearest your chosen keypad mounting location.
Position the metal plate 58" to 60" up from the floor of the
footbath.
Leave the control cable and metal plate attached here
until the finished wall is constructed. At that time, the metal
plate will be permanently attached flush to the outside
surface of the finished wall with two screws. The control
cable will then be secured to the metal plate with a cable
tie looped between the large and small center holes in the
metal plate.
TE:
NO
National Electrical Code requires that you
permanently separate the high- and low-voltage cables.
AB
116290-2-
Outlet Box
Stud
Outlet
Box
SIDE VIEW
Control Box
Metal Plate
Drip Loop
8
Stud
58" To 60"
From Floor
Control
Drip Loop
Cable
Control Cable
Control Cable
To Metal Plate
Control Box
Kohler Co., Kohler WI U.S.A.