Kohler Freshman K-4989-R Manual de instalación - Página 5
Navegue en línea o descargue pdf Manual de instalación para Sanitarios Kohler Freshman K-4989-R. Kohler Freshman K-4989-R 20 páginas. Urinal
También para Kohler Freshman K-4989-R: Manual de mantenimiento (9 páginas)
Wall
Wall Hangers
2. Install the Urinal
CAUTION: Risk of personal injury or product damage. Handle
with care. Vitreous china can break or chip if the product is
handled carelessly.
CAUTION: Risk of product damage. Do not overtighten the
bolts.
Install the wall hangers according to the roughing-in illustration.
Apply thread sealant tape to the pipe threads and install the
female collar to the waste pipe.
Place the gasket onto the female collar with the beveled surface
facing away from the collar.
Carefully position the urinal on the wall hangers.
Secure the urinal to the female collar using the screws and
washers provided.
3. Complete the Installation
Install the flush valve according to the manufacturer's
instructions.
Connect the water supply and complete the waste pipe
connections.
Turn on the water supply.
Flush and check the entire installation for leaks.
Repair as needed.
Kohler Co.
Installed Wall Hangers
Female
Collar
Screw
Gasket
5
Apply
sealant
tape.
Washer
1020646-2-C