Kohler K-10611T Instrucciones de instalación - Página 26
Navegue en línea o descargue pdf Instrucciones de instalación para Aseos Kohler K-10611T. Kohler K-10611T 27 páginas. Floor standing toilet
B. Adjust Inlet Valve
Hoist and reduce the water level in the tank by adjusting
the control pole. Turn the control pole counterclockwise to
lower down the floating box and reduce the water level of
the tank .turn the control pole clockwise to hoist the
floating box and increase the water level in the tank.
B.
TROUBLE SHOOTING PROCEDURES
TROUBLE SHOOTING PROCEDURES
Symptoms
No water fills in via inlet
valve
No drainage when
pressing the heavy and
slight drainage button
Too high or too low water
level
Leak of the toilet and
squat
Toilet does not flush
Toilet does not flush
completely
1263048-T01-D
Probable Causes
The inlet valve is closed.
Floating box of inlet valve is blocked by other parts.
Floating box of inlet valve is block by waste.
The adjustable board and the long screw are
wrongly installed.
The pole and the reversed lock are not connected.
The floating box of the inlet valve is not properly
adjusted.
The floating box of the inlet valve is blocked by
wastes, so the water is leaked from the overflow
pipe.
The rubber gasket is blocked by wastes.
A. No water supply.
B. The water supply stop is closed.
Filter screen is clogged.
Inlet Valve
Open inlet valve.
Readjust the position of other parts to avoid
contacting the floating box when it is
functioning.
Wash the floating box with clean water.
Reinstall the long screw.
Reinstall the reversed lock onto the pole of
the outlet valve.
Readjust the water level.
Readjust the position of other parts to avoid
contacting the floating box when it is
functioning.
Take out the outlet valve and clean the
wastes.
A. Wait for restoration of water supply.
B. Open the water supply stop.
Refer to wash filtration net.
-18-
Control Pole
Floating Box