Kohler Command 6 HP Manual del usuario - Página 9

Navegue en línea o descargue pdf Manual del usuario para Motor Kohler Command 6 HP. Kohler Command 6 HP 17 páginas. Horizontal crankshaft
También para Kohler Command 6 HP: Manual del usuario (16 páginas), Manual del usuario (16 páginas), Manual del usuario (16 páginas)

Kohler Command 6 HP Manual del usuario
Filler Neck
Bring Level Up
To Point Of
Overflow
Figure 8. Cutaway Showing Proper Oil Level.
5. If the level is low, add oil of the proper type, up to
the point of overflowing the filler neck. (Refer to "Oil
Type" on page 4.) Always check the level before
adding more oil.
NOTE: To prevent extensive engine wear or
damage, always maintain the proper oil
level in the crankcase. Never operate the
engine with the oil level below the point of
overflowing the filler neck.
Oil Sentry™
Some engines are equipped with an optional Oil
Sentry™ oil pressure switch monitor. If the oil pressure
decreases below an acceptable level, the Oil Sentry™
will either shut off the engine or activate a warning
signal, depending on the application.
NOTE: Make sure the oil level is checked BEFORE
EACH USE and is maintained up to the point
of overflowing the filter neck. This includes
engines equipped with Oil Sentry™.
Change Oil
For a new engine, change oil after the first 5 hours of
operation. Thereafter, change oil after every 100 hours
of operation.
For an overhauled engine or those rebuilt with a
new short block, use 10W-30 – weight service class
SG, SH, SJ or higher oil for the first 5 hours of
operation. Change the oil after this initial run-in period.
Refill with service class SG, SH, SJ or higher oil as
specified in the "Viscosity Grades" table (Figure 2) on
page 4.
Change the oil while the engine is still warm. The oil will
flow freely and carry away more impurities. Make sure
the engine is level when filling, checking, or changing
the oil.
Change the oil as follows (see Figures 7 and 8):
1. To keep dirt, debris, etc., out of the engine, clean
the area around the oil fill cap/dipstick before
removing it.
2. Remove the oil drain plug and oil fill/check plug.
Be sure to allow ample time for complete drainage.
3. Reinstall the drain plug. Make sure it is tightened to
17.6 N·m (13 ft. lb.) torque.
4. Fill the crankcase, with new oil of the proper type,
up to the point of overflowing the filler neck. Refer
to "Oil Type" on page 4. Always check the level
before adding more oil.
5. Reinstall the oil fill/check plug and tighten securely.
NOTE: To prevent extensive engine wear or
damage, always maintain the proper oil
level in the crankcase. Never operate the
engine with the oil level below the point of
overflowing the filler neck.
Service Precleaner and Air Cleaner Element
This engine is equipped with a replaceable, high
density paper air cleaner element. All engines are also
equipped with an oiled, foam precleaner which covers
the paper element. See Figure 9.
Check the air cleaner daily or before starting the
engine. Check for a buildup of dirt and debris around
the air cleaner system. Keep this area clean. Also
check for loose or damaged components. Replace all
bent or damaged air cleaner components.
NOTE: Operating the engine with loose or damaged
air cleaner components could allow unfiltered
air into the engine causing premature wear
and failure.
Service Precleaner
Wash and reoil the precleaner every 25 hours of
operation (more often under extremely dusty or dirty
conditions).
1. Loosen air cleaner cover retaining knob and
remove the cover.
2. Remove the precleaner from the paper element.
3. Wash the precleaner in warm water with detergent.
Rinse the precleaner thoroughly until all traces of
detergent are eliminated. Squeeze out excess
water (do not wring). Allow the precleaner to air dry.
9