Kohler Command PRO CH640 Manual del usuario - Página 8

Navegue en línea o descargue pdf Manual del usuario para Motor Kohler Command PRO CH640. Kohler Command PRO CH640 21 páginas. Liquefi ed petroleum gas (lpg) or lpg/natural gas (ng) fueled
También para Kohler Command PRO CH640: Manual del usuario (21 páginas), Manual del usuario (8 páginas), Manual del usuario (12 páginas), Manual del usuario (8 páginas)

Kohler Command PRO CH640 Manual del usuario
Normal maintenance, replacement or repair of emission control devices and systems may be performed by any
repair establishment or individual; however, warranty repairs must be performed by a Kohler authorized
service center.
For safety and health reasons, many states require special licensing or certifi cation for servicing LPG/NG fuel
systems. Check local and state regulations before choosing a repair establishment to perform fuel system repairs.
WARNING: Accidental Starts!
Disabling engine. Accidental starting can cause severe injury or death. Before working on the engine or equipment,
disable the engine as follows: 1) Disconnect the spark plug lead(s). 2) Disconnect negative (-) batt ery cable from batt ery.
Before disconnecting the negative (-) ground cable, make sure all switches are off . If on, a spark will occur at the ground cable
terminal which could cause an explosion if hydrogen gas or LPG/NG fuel vapors are present.

Maintenance Schedule

These required maintenance procedures should be performed at the frequency stated in the table. They should
also be included as part of any seasonal tune-up.
Frequency
Maintenance Required
• Check fuel gauge on propane (LPG) tank.
Daily or Before
• Check oil level.
Starting Engine
• Check air cleaner for dirty
• Check air intake and cooling areas, clean as necessary
• Service precleaner element
Every 25 Hours
• Replace air cleaner element
Every 100
• Change oil.
Hours
• Remove cooling shrouds and clean cooling areas
• Check oil cooler fi ns, clean as necessary (if equipped).
• Check spark plug condition and gap.
• Change oil fi lter.
Every 200
Hours
• Replace spark plugs.
Annually or
Every 300
Hours
• Check all lines (high pressure/vacuum) including fi tt ings for leaks.
Annually or
• Have electric starter serviced
Every 500
• Have lock-off /fi lter serviced
Hours
• Have combustion deposits removed if using non-synthetic oil.
• Drain regulator of accumulated fuel deposits (Nikki regulators only).
• Have regulator disassembled, cleaned, and reset
Every 1500
• Have vaporizer disassembled, cleaned, and serviced
Hours
1
Perform these maintenance procedures more frequently under extremely dusty, dirty conditions.
2
Have a Kohler Engine Service Dealer perform this service.
3
Must be performed by an Authorized Kohler Engine Dealer or qualifi ed LPG personnel only.
8

Maintenance Instructions

1
, loose, or damaged parts.
1
.
1
.
2
.
3
.
1
.
1
.
3
.
3
.