2.7 Battery Charger
The generator set is equipped with a 6-amp
float/equalize battery charger to maintain the engine
starting battery. The charger's power cord must be
connected to a 120 VAC power source. Figure 2-5
illustrates the battery charger.
The battery charger uses an AGS 10 inline fuse. The
fuse is located in the battery lead. See Figure 2-5.
1
INDICATOR
Red:
VOLTS= 11.8- -14.0
AMPS= 5.0- -6.0
Red & Green:
VOLTS= 14.0- -14.5
AMPS= 1.5- -5.0
Green:
VOLTS= 13.0- -13.6
AMPS= 0.1- -1.5
CAUTION:
To reduce the risk of elect rical shock,
connect only to properly gr ounded outlet.
INPUT: 115 VAC 50/60Hz @ 1.6A
OUTPUT: 12 VDC @ 6 Amps
MAX. BAT.: 180 Amp Hr. Max.
DATE:
Allowable Battery Types: Lead Acid a
4
3
1. LED indicators
2. AC power cord
3. Fuse
4. Battery leads, 12 VDC
Figure 2-5 6-Amp Float/Equalize Battery Charger
2.7.1
Battery Charger Operation
Figure 2-6 illustrates the three-stage charging method.
Red and green LEDs indicate charger operation. The
chart in Figure 2-7 describes the LED indicator
operation during each stage of the charging process.
18
Section 2 Operation
6 AMP AUTOMATIC
BATTERY CHARGER
R
C
US LISTED
BATTERY CHARGER
53AB
2608KH
nd Gel Cell
2
Figure 2-6 Charging Method
Display
Operating Condition
Red ON
When the red LED is on, it indicates the battery is
Green OFF
discharged and the battery charger is recharging at
the BULK rate (stage 1). This charging rate is
6 amps. While the red LED is on, the voltage
measured (with the battery charger on) will be
11.8--14 volts.
If the red LED stays on for more than 24 hours,
refer to Section 4.4 in this manual.
Red ON
When both the green and the red LEDs are on, the
Green ON
battery charger is charging at an ABSORPTION
rate of between 1.5 and 5 amps (stage 2). This
mode of charging gradually tops off your battery,
and reduces harmful sulfating. While both LEDs
are on, the voltage measured (with the battery
charger on) should be approximately
14.0--14.5 VDC.
If both LEDs stay on longer than 24 hours, refer to
Section 4.4 in this manual.
Red OFF
When the green LED is on, the battery charger is
Green ON
charging at a FLOAT or MAINTENANCE rate of
less than 1.5 amps (stage 3). Your battery is now
90% charged and ready for use. This float
charging current will gradually decrease to as low
as 0.1 amps as the battery reaches 100% charge.
It will now be kept at full charge without
overcharging.
If the green LED stays on when your battery is
known to be low, refer to Section 4.4 in this manual.
Figure 2-7 Battery Charger LED Indicator Functions
TP-6515 10/07