acaia AC002 Manual del usuario - Página 10

Navegue en línea o descargue pdf Manual del usuario para Scales acaia AC002. acaia AC002 15 páginas.
También para acaia AC002: Manual del usuario (15 páginas)

acaia AC002 Manual del usuario
Auto Start Mode Setting [ NOdE_3 ]
1. The Auto Start Mode is set to On by default.
• On: The Auto Start Mode is enabled.
• Off: The Auto Start Mode is disabled.
Bluetooth Setup Setting [ bt_SEt ]
1. Off: Bluetooth is disabled. The scale does not allow any Bluetooth connection.
2. On: Bluetooth is enabled. The scale allows Bluetooth connection. The user may connect the
scale with Acaia apps.
Battery Saving [ bA tt SA v E ]
1. The Acaia Pyxis will wait for the selected number of seconds to enter Battery Saving. The LED
display will dim to save power.
2. The default length of time before entering Battery Saving is 90 seconds.
Auto Start Sensitivity [ SEnSE ]
1. Minimum weight is decreased for more sensitivity. This is ideal for slower espresso shots in the
droplet icon modes. Stability depends on environmental noise.
2. The number indicates the sensitivity of flow detection in the droplet icon modes. Smaller value
indicates higher sensitivity, but is recommended only for stable working environments.
3. Tap the Tare button to toggle through the options.
Auto Reset [ Auto_rES ]
1. After a cup is removed, the timer will automatically reset. This setting gives you options on how
long to wait before resetting. It enables the user to pull successive shots of espresso quickly in
the three auto-start modes.
2. The number indicates the timeout value of timer reset after a cup is removed.
3. Tap the Tare button to toggle through the options.
Weighing Resolution Setting [ rESoL ]
1. The Weighing Resolution is set to the Default option; the division is 0.01 g for weights of 300 g
or less and 0.05 g for weights between 300 g and 500 g.
2. When the Weighing Resolution is set to High, the division is 0.01 g for weights of 300 g or less
and 0.02 g for weights between 300 g and 500 g.
Reset to Default Setting [ r ESE t. d ]
1. Select [ YES ] to set all settings to default value.
10