2.4.1

Controls and Indicators

The following table describes the controls and indicators
located at the controller:
Name
Start/Stop Switch
Use this switch to start and stop the
generator set. Press the switch to
the START position to start the
generator set. Press the switch to
the STOP position to stop the
generator set.
AC Circuit Breaker
The circuit breaker trips on
overcurrent. During maintenance of
the vehicle wiring, the circuit breaker
disconnects the generator set.
Place the circuit breaker in the ON
position to close the circuit breaker.
Input Fuse
This fuse protects the controller
circuitry.
Battery Charging
This fuse protects the battery
Fuse
charging circuitry.
Voltage Regulator
This fuse protects the voltage
Fuse
regulator circuitry.
Remote Start
A 6-pin connector on the controller's
Connector
back panel allows connection of the
(optional) remote start kits
Hourmeter
This meter records the total
generator set operating hours for
reference in maintenance
scheduling.
4
Section 2 Operation
Description
.
2.4.2

Starting the Generator Set

Hold the generator set controller start/stop switch or the
remote start/stop switch in the START position until the
unit starts.
2.4.3

Stopping the Generator Set

The following table describes the actions required to
stop the generator set:
Step
Step
1
Cooldown
Run the generator set at no load for 5 minutes to
ensure adequate engine cooldown.
2
Stopping
Place the controller start/stop switch or remote
start/stop switch in the STOP position.
Action
Action
TP-6081 4/00