SF53
CNC PLASMA Torch Height Controller
COM terminal is a common input terminal connected to the ARC, UP and DOWN
optocoupler contacts inside the device, according to the diagram located on the
cover.
OK output is activated when plasma ignition is detected and after the end of the
preset delay.Route and configure for a software input. Not required to operate.
UP output is activated when the measured voltage is lower than the Limit
voltage setpoint, reduced by entire the hysteresis voltage. Route and
configure for a software input.
DOWN output is activated when the measured voltage is higher than the Limit
voltage setpoint, reduced by entire the hysteresis voltage. Route and configure
for a software input.Note: No output signals are activated in case when only
the pilot arc is detected and when the main arc is broken.
Signal outputs should be connected to the CNC system in accordance with the
documentation of the CNC electronic system controlling the machine. For this,
we use inputs of outermost connectors HOME or LIMIT - THC control outputs
should be connected to the terminals the same way as limit switches connectors.
At the same time, the common COM terminal should be connected to the
CNC system to a common terminal for limit switches (it is usually a GND termi-
nal).
To reduce the possibility of the short-circuit entering the CNC system, the con-
nection should be made with a shielded cable - the shielding must be connected
to grounding on the CNC system side. Do not connect the shielding to the THC
controller side.
Start-up and operation:
The device is pre-configured at the factory and after the correct
connections are made, it immediately works properly with most plasma devices.
After switching power on, the THC controller's display shows an "animated"
"Aqtronic"message, and then show Limit value is presented for 1 second.
When the device is ready for operation it displays "- - - " which means it is
presentthere is no input voltage.
In this mode, by pressing the up/down keys, the threshold value can be modified
and thus set the height of the lens above the material.
To specify other parameters, hold both keys at the same time until you see the
HYS (hysteresis) parameter on the display. When you release the keys, you can
navigate through the menu parameters. In this state, by pressing the up/down
keys you can enter the value of the current parameter and change it by pressing
the up/down keys. Once the value is set, you can store the value by holding both
keys at the same time until you see the value flashing.
3