The Producer declines all responsibility in reference with whatever intervention on the
equipment from not skilled personnel!

2.0 TECHNICAL CHARACTERISTICS

2.1 General rules

Install the pump:
 On an horizontal reinforcement (ex: stoking tank) or on the pump
 Far from an hot source in dry places at maximum temperature of 45°C
 In a ventilated place and easily accessible by an operator for
 At a suitable height above the chemical up to a maximum height of 1.5
 Do not install the pump over the tank in presence of liquids that

2.2 Standard accessories supplied

1 Foot valve / Strainer.
1 Injection fitting / pressure loading valve.
2 meters opaque PE delivery tubing.
2 meters PVC clear suction tubing.
2 meters PVC clear priming tubing

2.3 Electrical characteristics

Power supply: 230 VAC- 50/60 HZ
Upon request some models with: 110VAC; 24/12 VDC – 24 Volt AC

2.4 Electric connection

CAUTION !!!!!
Verify that the earth system is perfectly functional and complies with the applicable
regulations. Ensure the unit is connected to a circuit protected by a highly sensitive (0.03A)
RCCB circuit breaker. If unsure please consult a competent electrician. Verify that the rated
values of the pump are compatible with those of the mains. Never install the pump directly
in parallel with inductive loads (e.g. motors/solenoid valves) if necessary, use an isolating
relay. There are 2 protection devices inside the pump: a varistor and a fuse.
Cod. ADSP7000177C Rev.0.0 (12/2020)
shelf (optional) so that the pump head stays always in vertical
position +/-15°.
and minimum 0°C.
periodical maintenance.
meters. If for xigency of the plant it's necessary to install the pump
under the level of the chemical, you need to use an injection valve or
an anti siphon valve.
emanate fumes unless it is hermetically closed.