AvL Technologies iDirect Interfaz y manual de referencia - Página 15
Navegue en línea o descargue pdf Interfaz y manual de referencia para Módem AvL Technologies iDirect. AvL Technologies iDirect 16 páginas.
4.3. Module Window
4.3.1. Device Window
From the AAQRemote GUI, open the Device Window. The module returns data from its communications in this
window.
Path
Main Window → View→ Device Window
Level 0
Item
Rx SNR
Modem Locked
AAQ Locked
Console Logged in
Telnet Logged in
Error Msg
Debug
Modem Locked
4.3.2. Device Control Window
A Device Control Window is not needed for monitoring operation and is not included in the software.
AvL Technologies
Figure 11 – Device Window
Reads back the modems singal to noise ratio (signal figure of merit)
The locked status of the iDirect modem.
The locked status of the controller.
A true or false indicator that shows if the controller has successfully
logged into the console interface.
A true or false indicator that shows if the controller has successfully
logged into the telnet interface
Displays the current error message:
None = No issues
Port size=X Set size=Y = User has not provided network/com settings
Bad Write to Modem = Controller was not successful sending data
Comm. Timeout = Controller did not receive data from the modem
Displays debug information such as a sample of the string sent to the
modem.
The locked status of the iDirect modem.
| Proprietary – Content is Subject to Change without Notice
iDirect Modem
Description
14