Aqua Computer AQUASTREAM XT USB Manual de usuario y funcionamiento - Página 9

Navegue en línea o descargue pdf Manual de usuario y funcionamiento para Bomba de agua Aqua Computer AQUASTREAM XT USB. Aqua Computer AQUASTREAM XT USB 16 páginas.
También para Aqua Computer AQUASTREAM XT USB: Manual de uso e instalación (20 páginas)

Aqua Computer AQUASTREAM XT USB Manual de usuario y funcionamiento
aqua
computer
Version 11/2007
MANUAL AQUASTREAM XT
7. Inbetriebnahme
First turn off your PC, or remove the main PSU cable if no power-switch is
present. Remove all cables of the PSU (e.g. from non removable disks, optical
storage drives or graphic cards), especially also the 4pin ATX12V power
supply. Attach the pump to the power supply unit with one of the 4-pin Molex
plugs to establish the power supply.
To be able to operate your pump when filling the system, you must now either
start the PC power supply with the enclosed ATX bridging plug or attach the
pump to a second power supply unit.
For starting the power supply unit you put the ATX
bridging plug on the ATX plug of the power supply
unit. The power supply starts after you have put the
plug on. To turn the power supply unit off, you
simply
unplug
the
plug
again.
There is the possibility that your power supply does
not run with the ATX bridging plug. In this case add
CD disk drives and hard disks to the power supply unit.
A red control LED which should flash now is at the lower rear opening at the
pump. If the LED does not flash and shines durably there is an operating
failure . In that case a reset which is described on page 14 can help.
To activate the deaeration mode you put the enclosed jumper on the
connection with the marking "deaeration/ext. Temp". Putting the jumper on
must be carried out while the pump already runs. To end the deaeration
mode you simply remove the jumper again. The pump is in the normal
operating mode now again.

8. aquasuite Software

With the Windows software aquasuite an extensive software is at your
disposal which can be used for all aqua computer products with USB
interface. The software serves the control and monitoring. The installation of
the software is not imperative for the operation of the pump.
Note: Depending on used variant of the aquastream XT, some of the
described functions in the further text are not available in the software. These
can, however, be activated by the acquisition of a key afterwards.
If you change the settings and want to keep them, then you can store these
permanently into the pump by using the function "save settings" in the menu
"aquastream XT".
© 2007
Aqua Computer GmbH und Co. KG
Page 9
Gelliehäuser Str. 1 – D-37130 Gleichen - Germany