14. Alarm configuration(aquasuite)
14. Alarm configuration(aquasuite)
14. Alarm configuration(aquasuite)
14. Alarm configuration(aquasuite)
Select "Alarm configuration" from the device list for the device to be configured.
14.1. Speed signal/Output
14.1. Speed signal/Output
14.1. Speed signal/Output
14.1. Speed signal/Output
Select the signal to be provided through the speed signal output. Available options
are the speed signal of a connected fan or flow sensor, current pump speed or an
artificial speed signal. The check box "Switch off speed signal in case of alarm
condition" determines output behavior during alarm conditions.
14.2. Alarm reporting and alarm limits
14.2. Alarm reporting and alarm limits
14.2. Alarm reporting and alarm limits
14.2. Alarm reporting and alarm limits
Select the data sources to be monitored and set appropriate alarm limits. If the
current reading is below the lower limit or higher than the upper limit, an alarm
will be raised if the check box "Activate alarm evaluation" is set for this value. All
sources that currently raise an alarm are highlighted with a red background color
in the software.
Make sure only to use readings for alarm evaluation that are functional with your
specific setup.
15. System settings aquastream XT (aquasuite)
15. System settings aquastream XT (aquasuite)
15. System settings aquastream XT (aquasuite)
15. System settings aquastream XT (aquasuite)
Select "System" from the device list for the device to be configured.
15.1. Device information
15.1. Device information
15.1. Device information
15.1. Device information
The details displayed here might be required when you contact our service for sup-
port.
15.2. Factory defaults
15.2. Factory defaults
15.2. Factory defaults
15.2. Factory defaults
Click the button "Reset device to factory defaults" for a complete reset of all set-
tings. You will have to completely reconfigure the device after resetting it to factory
defaults!
15.3. Key management
15.3. Key management
15.3. Key management
15.3. Key management
In order to upgrade your aquastream XT pump to a higher version, you will need
the serial number and the device key from the "Device information" section of this
page. Order the desired upgrade from the Aqua Computer web shop and enter
serial number and device key into the "Annotations" field during the checkout pro-
cess. For your convenience, you can also click the button "Buy upgrade key" to
display a help page with all necessary information.
After receiving your activation key from Aqua Computer, enter the key to the box
labeled "Enter upgrade key" and click the "Apply" button. The pump needs to be
restarted after entering the activation key. To do so, save all settings into the pump
© 2007-2013