Avlite AV-OL-CMI Manual de instalación y mantenimiento - Página 16

Navegue en línea o descargue pdf Manual de instalación y mantenimiento para Equipos de iluminación Avlite AV-OL-CMI. Avlite AV-OL-CMI 20 páginas. Combined medium intensity obstruction light

Avlite AV-OL-CMI Manual de instalación y mantenimiento
Battery Status
B
This function reads the battery status. The response from the light is:
4 flashes = High Voltage
3 flashes = Good Voltage
2 flashes = Low Voltage
1 flashes = Cutoff Voltage or below
Example Key sequence:
Error/Acknowledge Indication
If the key sequence is invalid, or an out of bounds value is attempted to be set, the light flashes 5 times for 1 second.
(The command then needs to be sent from the start.)
Example key sequence: (Set the intensity level to 5 – undefined.)
The light flashes 5 times for 1 second.
When a key sequence has been entered successfully the light will respond acknowledgement with a 1 second flash.
Medium Intensity Obstruction Light
16
AV-OL-MI
R
B
T/C
5
I
T/C