Aqua Creek Products F-VGRPL Manual de instrucciones - Página 4
Navegue en línea o descargue pdf Manual de instrucciones para Sistemas de elevación Aqua Creek Products F-VGRPL. Aqua Creek Products F-VGRPL 14 páginas. Portable lift
ADA REQUIREMENTS:
The Mighty Voyager Lift is completely ADA compliant when installed correctly.
The installation must meet the following requirements:
•
Clear deck space dimensions (see FIGURE 1)
•
Centerline of seat 16 inches minimum from the pool edge
•
Deck slope no greater than 1:48
•
The seat must go at least 18 inches into the water. The lift should be
installed at a location with 44 inches to 48 inches of depth (deck to pool fl oor)
*Setback distance will vary on curved walls, contact Aqua Creek
NOTE: The FIXING BOLT is used to fi x the portable lift in place and to ensure that it remains in
an ADA approved location. This makes the lift fully ADA compliant.
ADA REQUIRED
CLEAR DECK SPACE
36.0
C L
16.0
MIN
4
Copyright © 2020 Aqua Creek Products All Rights Reserved
Installation: ADA Guidelines
77.6
48.0
12.0
POOL WALL
101.5
FIGURE 1
FIXING BOLT
BELOW CART
OUTRIGGERS
MUST BE
DEPLOYED
PRIOR TO USE
Revised 10/21/20