UFC-420/440 water Filtration system
secure
end
Drain
filtration process
Water filtration in the UFC Series is accomplished
using two modes: Flush Interval Mode, shown as Fi on
the LED Display and Flush Duration Mode (Fd on LED
display). During the Flush Interval, water enters the
inlet and flows through the filter element before exiting
the Permeate outlet as usable product water.
After a certain period of time, depending upon water
quality, the filter has to be cleaned. This is accom-
plished through the Flush Duration Mode. During
this mode, the drain valve opens and flushes the
membrane to remove debris collected inside the
membrane walls.
nOte: both the flush Interval mode and the flush
Duration mode can be automated by programming
the timer. During the flush Interval mode, the valve
is not powered in order to keep water filtering during
a power outage.
leD Display
Fi - Flush Interval Mode is the time between flushings
and is displayed in minutes or hours.
Fd - Flush Duration Mode is the amount of time used
to flush and remove debris from filter cartridge and
is displayed in seconds.
FL - Manual Flush Mode operation, solenoid is
manually activated by the user.
OperatIOn
Drain line
from system
2"
minimum
standpipe
secure
figure 3. proper Draining
starting the system
Power up the unit.
The LED read-out displays the following for about two
seconds each:
1. 8.8
2. Fd followed by its time settings in seconds.
3. Fi and its time setting, in minutes or hours.
The Fd, Fi sequence repeats for 30 seconds
after which, the unit automatically returns to the
Flush Interval Mode (Fi). The time setting for Fi
will be displayed and the decimal point will flash in
one second intervals.
nOte: the timer can be programmed immediately
after start-up or while in flush Interval mode.
10
Drain line
from system
end
figure 4. leD Display, front panel
P/N 1010908 Rev. A 03/12
A.J. Antunes & Co.
2"
minimum
floor
Drain