COZY 000 TO 50 Folleto y especificaciones - Página 2

Navegue en línea o descargue pdf Folleto y especificaciones para Horno COZY 000 TO 50. COZY 000 TO 50 2 páginas. Gravity wall furnaces

COZY 000 TO 50 Folleto y especificaciones
Single Wall Furnace models
may be equipped with a
Rear Register Kit and Grille
(40542) allowing warm air
to circulate into the adjoin-
ing room. Adjustable vent
controls air flow.
Resettable Blocked Flue
Safety Device automatically
shuts the unit off in the
event of flue blockage or
incorrect vent installation.
Continuous Seam-Welded
Combustion Chamber
constructed of heavy gauge
aluminized steel, maximizes
heat transfer. Warranted for
ten (10) years.
Model
Type
Number
Control
SINGLE
W251
Bulb
WALL
W255
M. Volt
W252
Bulb
W256
M. Volt
W351
Bulb
W355
M. Volt
W352
Bulb
W356
M. Volt
DUAL
W501
Bulb
WALL
W505
M. Volt
W502
Bulb
W506
M. Volt
Form No. GWF 15M 10/05
Engineered for years of efficient, trouble free service
Featuring 20 gauge aluminized combustion chambers, warranted for 10 years.
Free Standing Kit (FSK)
allows single wall furnaces
to be surface mounted.
Eliminates cutting holes in
wall — ideal for masonry
wall installation. For use
with ceilings up to 8'6" tall;
adds 4-3/4" to unit depth.
(vent pipe not included).
Weight: 16 lbs.

SPECIFICATIONS

Type
BTU/Hr.
Vent
Gas
Gas
Input
Size
Inlet
Nat.
25,000
4"
1/2"
Nat.
25,000
4"
1/2"
L.P.
25,000
4"
1/2"
L.P.
25,000
4"
1/2"
Nat.
35,000
4"
1/2"
Nat.
35,000
4"
1/2"
L.P.
35,000
4"
1/2"
L.P.
35,000
4"
1/2"
Nat.
50,000
4"
1/2"
Nat.
50,000
4"
1/2"
L.P.
50,000
4"
1/2"
L.P.
50,000
4"
1/2"
Fan accessory kit (WFF81)
available for installation on
top of furnace to increase
circulation. Adds only 10
to height of casing. Fits
flush against wall — not
recessed. Operates at
50 CFM on 115V.
ROUGH IN
Easy installation method reduces installation time to
minutes . . . only one man needed. New positive fastening
tabs hold grille in place . . . makes installation a snap!
1
"
14
/
MIN.
4
14
1
/
"
MAX.
2
"
4
ROUGH-IN DIMENSIONS
Finished
Shipping
Dimensions
Weight
16
1
/
" W
68" H
6
1
/
" D
90 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
90 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
90 lbs.
2
2
1
1
16
/
" W
68" H
6
/
" D
90 lbs.
2
2
1
1
16
/
" W
68" H
6
/
" D
90 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
90 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
90 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
90 lbs.
2
2
1
1
16
/
" W
68" H
6
/
" D
134 lbs.
2
2
1
1
16
/
" W
68" H
6
/
" D
134 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
134 lbs.
2
2
16
1
/
" W
68" H
6
1
/
" D
134 lbs.
2
2
One or two fan kits may be used on dual-wall furnace.
Optional Night Setback
Thermostat (XL 110 / XL411)
provides economic as well
1
/
"
as convenient operation.
2
5
12
/
"
8
PLASTER
OPENING
FOR REAR
1
"
8
/
REGISTER
4
MODEL
REAR
65
3
"
/
4
REGISTER
FRAME
45
3
/
"
4
PLASTER
PLATE
4
"
REAR REGISTER OUTLET LOCATION
Rear Register Kit
Fan Kit
Model
Weight
Model
Weight
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
40542
5 lbs.
WFF81
10 lbs.
N/A
N/A
WFF81
10 lbs.
N/A
N/A
WFF81
10 lbs.
N/A
N/A
WFF81
10 lbs.
N/A
N/A
WFF81
10 lbs.
NAIL TO
STUDS
OPENING
7/8
"
FROM
EACH STUD
STUD
PLASTER