Aqua Free AS DataLog Instrucciones de uso e instalación - Página 3

Navegue en línea o descargue pdf Instrucciones de uso e instalación para Instrumentos de medida Aqua Free AS DataLog. Aqua Free AS DataLog 5 páginas.

5

Technical data

Dimensions:
Measurement Interval:
Measuring accuracy*
Operating voltage:
Batteries used:
Service life:
Data storage:
Medium:
* The temperature measured is dependent on the pipe system and technical
equipment.
6

Scope of supply

AS DataLog recorder with ring sensor
G3/8" adapter
(for securing the sensor to the FLUSH system)
hexagon socket (10 mm)
USB cable (Micro B to A)
3.6-Volt AA battery
replacement sealings (G⅜")
set of operating instructions
battery replacement labels
transport case
4
L: 92 mm; W: 68 mm;
H: 30 mmh
30 seconds
±1 °C after 3 minutes
Flush duration
3,6 Volt
1× 3.6-Volt AA battery
(6LR61, alkaline)
min. two months
on one battery
on internal SD card
Drinking /
tap water
7

Handling

7.1 Installation:
The "AS DataLog" recording system is used in combi-
nation with the FLUSH 2.0 system. This requires
converting the flushing system as follows:
1. Unscrew the hygiene stream former at the outlet of
the FLUSH 2.0 system.
2. Use the Allen Key provided remove the black adapter
and store it safely in the FLUSH 2.0 case.
3. Replace the seal in the outlet of the FLUSH 2.0
system.
4. Position the sensor on the chrome-plated adapter,
ensuring that the copper-coloured side faces the
adapter, and screw the adapter tightly to the FLUSH
2.0 system using the hexagonal socket.
Sensor
adapter
5. Connect the overall system to a tap and programme
a manual flush at the FLUSH 2.0 system to check
whether water leaks from the connection point
between the FLUSH 2.0 system and chrome-plated
adapter. If necessary, use the Allen key to tighten the
adapter.
6. Re-connect the hygiene stream former to the adapter.
7. Secure the "AS DataLog" system outside the
washbasin using the suction cup.
Ring sensor
Flush 2.0
(sensor adapter
on copper-colou-
red side)
5