DeZurik POWERRAC R3 Manual de instalación y funcionamiento - Página 13
Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Controlador DeZurik POWERRAC R3. DeZurik POWERRAC R3 15 páginas. Cylinder actuator
Adjust only the right-side lock screw to lock the actuator in the open position. Adjusting
the wrong screw does not lock the actuator, and can result in personal injury or
equipment damage.
2.
Loosen the jam nut (B65) on the right side lock screw (B64), as viewed when facing the top of
the heads of the lock screws. Hold the lock screw from turning, and turn the jam nut several
turns counterclockwise, to the head of the lock screw.
3.
Turn the right side lock screw clockwise several turns until resistance is felt from the lock
screw contacting the notch in the gear (B8). Tighten the lock screw to 5 to 10 foot pounds (7
to 14 Nm) to assure that the lock screw is contacting the gear.
4.
Turn the right side jam nut clockwise against the actuator housing. While holding the lock
screw from turning, tighten the jam nut to 140 ± 18 foot pounds (190 ± 24 Nm).
5.
Place and lock the lockout cover assembly (B60) on the head of the right side lock screw.
August 2016
R3 PowerRac
Page 13
DeZURIK
Cylinder Actuator
TM
D10359