Aqua Lung CORE Manual de servicio - Página 5

Navegue en línea o descargue pdf Manual de servicio para Controlador Aqua Lung CORE. Aqua Lung CORE 18 páginas.

Aqua Lung CORE Manual de servicio
1.
In order to carry out the procedures described in this manual correctly, it is important that you follow the steps in the exact order
indicated. Read the manual through completely so that you become familiar with all the procedures, the special tools and the
replacement parts, before starting to disassemble the product. Keep this manual open near to you so that you can refer to it step
by step. Do not rely on your memory.
2.
All servicing and repair procedures should be carried out in a workshop that is clean, well lit, easy to access and specially fitted
for the purpose.
3.
The regulator body should never be directly held in the jaws of a vice. To hold the body, screw the tool (116230) into a HP or
MP port and then grip the tool with the vice.
4.
Once the regulator has been disassembled, the re-usable components should be separated from the components that need to
be replaced. Fragile items with seats or crowns with critical sealing surfaces should be separated and protected during servicing
in order to prevent any damage.
5.
Use only spare parts from Aqua Lung service kits. Never replace an Aqua Lung part with one from another manufacturer, even
if it appears similar.
6.
Never re-use regulator parts which should be replaced on the pretext that the regulator has seen little use since its manufacture
or since its last service.
7.
When reassembling, check that the torque used conforms with that shown in Table 4. Torque values. Some parts can be
irretrievably damaged if the acceptable torque is exceeded.
The conventions described below define the actions to be carried out when an instruction is given.
1.
Unscrew: to unscrew a threaded part, turn it anti-clockwise.
2.
Screw: to screw a threaded part, turn it clockwise.
3.
Remove the O-ring: To remove an O-ring follow the method below, using the special tool (506001) provided for this purpose.
Any tool that could damage the O-ring should be avoided. In every case, replace the O-ring removed with a new one.
Press simultaneously on the two sides
of the O-ring in order to form an 'eye'.
Insert the special tool (506001) into this
eye to remove the O-ring.
4.
The acronyms used:
LP: Low Pressure
MP: Medium Pressure (or IP: Intermediate Pressure)
HP: High Pressure
5.
Bracket numbers indicate components references from exploded views.
nd
Service Manual Core 2
Rev. 05/2015

GENERAL INSTRUCTIONS

GENERAL CONVENTIONS

stage
nd
Service Manual Core 2
stage