DFE TRUETENSION TA1 Manual de inicio rápido - Página 6

Navegue en línea o descargue pdf Manual de inicio rápido para Amplificador DFE TRUETENSION TA1. DFE TRUETENSION TA1 12 páginas. Tension amplifier
También para DFE TRUETENSION TA1: Manual de instrucciones (16 páginas)

DFE TRUETENSION TA1 Manual de inicio rápido
4
CALIBRATION AND ZERO
A calibration process must be performed before your amplifier is ready to indicate
tension. Select an appropriate calibration weight. The weight determines the value of
web tension that will produce full output of the TA1. For example: A 15 lb weight will
result in full output at 150 lbs of tension if the 10% calibration is performed. If a calibra-
tion of 25% is used, a calibration weight of 15 lbs will result in a full output at 60 lbs of
tension. The first step of any calibration is Zeroing out the amplifier.
Zero Button - Used to zero the amplifier
Status LED - Indicator light for amplifier status
Cal Button - Used to calibrate the amplifier