INSTALLATION (continued)
2.3

STANDARD ELECTRICAL CONNECTIONS

1. Power Input

Power should be sourced to the 1100TV on Pins 16 (GND) and 15 (+24 VDC).

2. Tension Output (Optional)

The tension output signal is provided in two options:
0-10 VDC is available on Pins 9 (Return) and 11 (0-10 VDC)
4-20 mA is available on Pins 9 (Return) and 10 (4-20 mA)

3. Transducers / Load Cells

Use the appropriate color connections for the type of tension transducer being connected.
POWER and SIGNAL CONNECTIONS
3