Aqua Medic SP 3000 Manual de instrucciones - Página 6

Navegue en línea o descargue pdf Manual de instrucciones para Acuarios Aqua Medic SP 3000. Aqua Medic SP 3000 6 páginas. Dosing pump

Aqua Medic SP 3000 Manual de instrucciones

7. Maintenance

The pump hose and the motor are consumable and have to be maintained and changed regularly.
Pump hose: The pump hose has a lifetime of approx. 3 million compressions and after this useage must be
replaced. If the pump is operated continously the hose should be changed every 3 – 4 months. We recommend
using only an original Aqua Medic spare pump hose assembly which is supplied complete with fittings.
Grease: Before the hose is installed it has to be greased. The pump will only operate properly if the hose is
effectively greased.
Heat: During continous operation the motor may heat up as high as 70°C. This is normal and has no effect on
performance or the life. However too little grease on the pump hose may cause malfunction of the motor and
overheating.
Drive wheel with rollers: The plastic driving wheel and the rollers are designed for a long life. Nevertheless it
may become necessary to change the assembly which should be undertaken using the following procedure:
Remove the pump hose by pushing the fittings out of the housing. The drive wheel can now be pulled off the
shaft as it is a pressed fitting.
Motor: The motor has a lifetime of >10,000 hours. To replace the motor remove the drive wheel assembly. Undo
the 4 screws in the backplate. Now remove the backplate and protection plate. Undo the power cable connection
from the connector block and remove the 2 screws securing the motor to the housing.
To fit the new motor reverse the above process.
Safety instructions
The pump may only be used indoors. Before undertaking any work on the pump,
disconnect the power plug from the mains.

8. Warranty

Should any defect in material or workmanship be found within twenty four months of the date of purchase
undertakes to repair or, at our option, replace the defective part free of charge – always provided
the product has been installed correctly, is used for the purpose that was intended by us, is used in accordance
with the operating instructions and is returned to us carriage paid. The warranty term is not applicable on the all
consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's name, the
model number and date of purchase, or a Guarantee Card if appropriate. This warranty may not apply if any
model or production number has been altered, deleted or removed, unauthorised persons or organisations have
executed repairs, modifications or alterations, or damage is caused by accident, misuse or neglect.
We regret we are unable to accept any liability for any consequential loss.
Please note that the product is not defective under the terms of this Warranty where the product, or any of its
component parts, was not originally designed and / or manufactured for the market in which it is used.
These statements do not affect your statutory rights as a customer.
If your
product does not appear to be working correctly or appears to be defective please contact
your dealer in the first instance.
Before calling your dealer please ensure you have read and understood the operating instructions. If you have
any questions your dealer cannot answer please contact us
Our policy is one of continual technical improvement and we reserve the right to modify and adjust the
specification of our products without prior notification
- Bissendorf 11/ 02
6