Aqua Medic T controller twin Manual de instrucciones - Página 5

Navegue en línea o descargue pdf Manual de instrucciones para Unidad de control Aqua Medic T controller twin. Aqua Medic T controller twin 9 páginas. Digital temperature monitor and controller for controlling heating and cooling units
También para Aqua Medic T controller twin: Manual de instrucciones (13 páginas)

Aqua Medic T controller twin Manual de instrucciones
1. Included in shipment
The Aqua Medic T controller twin is generally delivered with a saltwater-resistant temperature sensor.
The unit is ready for connection. The units to be controlled (heaters, fans, coolers) are connected to
the double socket.
2. Description
Socket No. 1 is provided for controlling fans or coolers. The maximum output is approx. 1,200 watts.
Due to the high starting current, cooling units may be connected only to a power consumption of
460 watts. Heaters of any type (i. e. glass or metal aquarium heaters, low voltage heating cables
with transformer, warm water supply by a magnetic valve) can be connected to socket No. 2. The
maximum output again is approx. 1,200 watts.
3. Installation
-
Connect to 220 - 240 V power source.
-
Place the temperature sensor into the aquarium and fix it with an Aqua Medic electrode holder.
After a few minutes, the actual aquarium water temperature is indicated.
Pict. 1: T controller twin
1. Socket – cooling
2. Socket – heating
3. SAVE key
4. Arrow keys to adjust the parameter
5. SET key
6. Temperature sensor incl. sucker
4. Adjustion
To program the controller, press the "SET" key. The °C symbol begins to flash and the setpoint can
be set to the requested value using the arrow keys. If no key is pressed for five seconds, the display
returns to the measuring mode. Holding the respective arrow key pressed for a few seconds, the
display starts to run faster.
After pressing the "SET" key again, the display goes to the setting for the control precision. Use the
arrow keys to set the desired value in steps of 0.1° C. This is done both for heating and for cooling.
By pressing the "SET" key again, the unit jumps back again to the alarm value.
5