RF-LPS Pin Header Truth Table
DIP #1
DIP #3
TX BUTTON 1
ON
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
(default)
(default)
OFF
OFF
OFF
ON
OFF
From the above table, the following can be noted:
•
VT always goes high upon a button press, and may be used to indicate a valid transmission. VT
remains HIGH for the duration of the button press and then goes LOW
•
Each button press latches the states of D1, D2 and D3
•
D1 toggles state from Button 1 press to Button 2 press
•
D3 is always HIGH if DIP switch 10 is in the OFF position
•
D3 is always LOW if DIP switch 10 is in the ON position
•
D2 toggles state between button 1 press and button 2 press when DIP switches 1 and 3 are not
both set to ON or OFF
The RF-LPS pin header for VT, D1,D2 and D3 may be used to connect to external devices for custom
applications.
Disclaimer:
Technical specifications are subject to change without notice. Whilst every effort has been made to ensure the accuracy of the information contained
in this document, ABACOM Technologies Inc. does not assume responsibility for any errors or omissions that may exist. ABACOM Technologies Inc.
does not assume responsibility for any damage caused through use or misuse of their products and the onus lies entirely with the end user in deter-
mining the suitability of, and use of, the product for any particular application. ABACOM Technologies Inc. products are not recommended for appli-
cations where human life may be at risk.
ABACOM Technologies, Inc.
TX BUTTON 2
OFF
ON
OFF
ON
OFF
ON
OFF
ON
•
383 Bering Ave • Etobicoke • ON • M8Z 3B1 • Tel +1(416)236-3858 • Fax +1(416)236-8866
www.abacom-tech.com
VT
D1
D2
1
0
0
1
1
0
1
0
0
1
1
1
1
0
1
1
1
0
1
0
1
1
1
1
D3
RF-LPS O/P
1 or 0
OFF
1 or 0
ON
1 or 0
OFF
1 or 0
ON
1 or 0
OFF
1 or 0
ON
1 or 0
OFF
1 or 0
ON