Installation requirements.

XL, XT, XR.
Components for Billi Sahara
310, 320, 360 & 3120 Models – XL, XT, XR
Before commencing installation,
ensure you have identified the following.
1. Underbench module
2. Dispenser upper with tubing
3. Dispenser base & mount
4. Barb locking bush
5. 4mm chrome screw & allen key
6. Large washer
7. Tube spring clamps x 3
8. 600mm flexible braided hose
10. Filter cartridge (installed)
11. User guide
12 Warranty registration card
13. Warning label
Additional Components – XR
14. Remote panel kit
Determine Unit Location
Plan the installation. Dispenser tube lengths,
position of power and water outlets, required
air space around the underbench module and
access for service must be considered before
cutting tube lengths. Refer to Diagrams 1 and 2.
Unit must be installed horizontally with display
panel facing to front of cupboard. The Sahara is
designed for internal installation only.
Model
Height
Width
Sahara 310
340mm 180mm 365mm 10mm
Sahara /
Sahara Plus
340mm 180mm 460mm 10mm
320, 360, 3120
Water Supply
The Sahara must only be connected to a cold
water supply. A ½" BSP stop tap (not supplied)
is to be installed in an easily accessible position
within 600mm from the Sahara water
supply inlet.
Dynamic water supply pressure:
Min. 250 kPa, max. 1000 kPa. (excludes
Sahara 310*)
Minimum water supply: 6 l/m at 250 kPa
Supply temp: min. 5°C, max. 30°C.
* Sahara 310 supply pressure: Min 200
kPa - 500kPa. Where supply pressure is
greater than 500 kPa a PLV must be fitted.
Billi recommends PLV's with anti-hammer
properties.
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
2
Power Requirements
A single 3 pin GPO is required. A dedicated
circuit should be provided and must be fitted
with an earth leakage protection device (RCD).
An externally fitted RCD device is acceptable
Sa hara 310, 320, 320 Plus, 360 and 360 Plus
require a 10 amp rating.
Sahara 3120 and 3120 Plus require a 15 amp
rating.
All Sahara models are supplied with a 1 metre
flex cord and plug.
Min side
Depth
clearance
20mm
180mm
340mm
FRONT
Tubing
Power
removed
Outlet
for clarity
Cupboard Dimensions:
230mm Minimum Width
523mm Minimum Depth
Stop Tap
(Installed by Plumber)
Max 450mm from Unit
20mm
175mm
205mm
10mm
bench
thickness
1mm-48mm
35mm
Tubing
removed
for clarity
20mm
460mm
340mm
SIDE
460mm
180mm
TOP
800mm
60mm
Tube Length
Minimum
Supplied
Clearance
Diagram 1
130mm
70mm
Diagram 2
Diagram 3