Installation
requirements.
Components for B-3000
Before commencing installation,
ensure you have identified the following.
1. Chilled Water Module
2. Installation Requirements
3. Installation Hardware and Dispenser
4. Warranty
Water Supply
A single cold water supply is required.
Supply Pressure: 200 – 1000 Kpa
Supply Temperature: 5°C – 30°C
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
Power Requirements
A single 10 amp standard power outlet is
required. Chiller module is supplied with
1 metre of flex cord and plug.
Drainage
A drainage point, such as a dishwasher nipple
or a tundish, is required.
2
Power
Outlet
800mm
Cupboard Dimensions:
Tube Length
220mm Minimum Width
Supplied
365mm Minimum Depth
Stop Tap
(Installed by Plumber)
Max 450mm from Unit
113mm
233mm
37mm
Diagram 1
bench
thickness
1mm-37mm
Diagram 2