Error
Description
Code
3221
Warning: DC bus
undervoltage
3222
DC bus voltage too low for
switch-on
4210
PU: Overtemperature fault
4281
Heatsink fan warning
4310
Error: Motor
overtemperature
5112
24-V supply fault
5180
24-V supply overload
6280
Trigger/functions connected
incorrectly
7180
Motor overcurrent
9080
Keypad removed
FF02
Error: Brake resistor overload Fault
FF06
Motor overspeed
FF36
Warning: Brake resistor
overload
FF37
Automatic start disabled
FF85
Keypad full control active
CPE Systems Inc.
|
Classification Remedy
Warning
Warning
Fault
Warning
Fault
Warning
Warning
Trouble
Fault
Fault
Fault
Warning
Fault
Warning
www.cpesystems.com
Check mains voltage
Check fuses
Check DC bus voltage
Check mains settings
Check mains voltage
Check fuses
Check mains settings
Check mains voltage
Provide for sufficient cooling of the device
(display of the heatsink temperature in
P117.01)
Clean fan and ventilation slots. If required,
replace fan
Reduce switching frequency (P305.00)
Clean fan and ventilation slots. If required,
replace fan. The fans can be unlocked via
locking hooks and can then be removed
Check drive sizing
Check motor thermal sensor and wiring
(X109/T1 and X109/T2)
Check optional external 24-V voltage supply
(terminal X3/24E), if connected
Check mains voltage
Check 24-V output and digital outputs for
earth fault or overload
Check and correct the assignment of the
triggers to the functions
With keypad or network control, the two
functions "Inverter enable" (P400.01) and
"Run" (P400.02) can also be set to "Constant
TRUE{1}" to start the motor
Check motor load
Check drive sizing
Adapt the set error threshold (P353.01)
Plug on the keypad again or activate another
control source
Check drive sizing
Check settings for the braking energy
management
Note: The error will be reset if the thermal load
falls below the error threshold (P70180) of - 20%
Adapt the maximum motor speed (P322.00)
and the error threshold (P350.01)
Check drive sizing
Check settings for the braking energy
management
Note: The warning will be reset if the thermal
load falls below the warning threshold (P707.08)
of - 20%
Deactivate start command and reset error
To exit the control mode, press the control
keypad key
|
+1 800 668 2268
Blocking
Reset
Times
Possible
0
Yes
0
Yes
0
Yes
0
Yes
5
Yes
0
Yes
0
Yes
0
Yes
1
Yes
0
Yes
5
Yes
1
Yes
0
Yes
0
Yes
0
Yes
|
18