CPE C114 Manual - Página 18
Navegue en línea o descargue pdf Manual para Bomba de agua CPE C114. CPE C114 19 páginas. Portable pump
Error
Description
Code
3221
Warning: DC bus
undervoltage
3222
DC bus voltage too low for
switch-on
4210
PU: Overtemperature fault
4281
Heatsink fan warning
4310
Error: Motor
overtemperature
5112
24-V supply fault
5180
24-V supply overload
6280
Trigger/functions connected
incorrectly
7180
Motor overcurrent
9080
Keypad removed
FF02
Error: Brake resistor overload Fault
FF06
Motor overspeed
FF36
Warning: Brake resistor
overload
FF37
Automatic start disabled
FF85
Keypad full control active
CPE Systems Inc.
|
Classification Remedy
Warning
Warning
Fault
Warning
Fault
Warning
Warning
Trouble
Fault
Fault
Fault
Warning
Fault
Warning
www.cpesystems.com
•
Check mains voltage
•
Check fuses
•
Check DC bus voltage
•
Check mains settings
•
Check mains voltage
•
Check fuses
•
Check mains settings
•
Check mains voltage
•
Provide for sufficient cooling of the device
(display of the heatsink temperature in
P117.01)
•
Clean fan and ventilation slots. If required,
replace fan
•
Reduce switching frequency (P305.00)
•
Clean fan and ventilation slots. If required,
replace fan. The fans can be unlocked via
locking hooks and can then be removed
•
Check drive sizing
•
Check motor thermal sensor and wiring
(X109/T1 and X109/T2)
•
Check optional external 24-V voltage supply
(terminal X3/24E), if connected
•
Check mains voltage
•
Check 24-V output and digital outputs for
earth fault or overload
•
Check and correct the assignment of the
triggers to the functions
•
With keypad or network control, the two
functions "Inverter enable" (P400.01) and
"Run" (P400.02) can also be set to "Constant
TRUE{1}" to start the motor
•
Check motor load
•
Check drive sizing
•
Adapt the set error threshold (P353.01)
•
Plug on the keypad again or activate another
control source
•
Check drive sizing
•
Check settings for the braking energy
management
Note: The error will be reset if the thermal load
falls below the error threshold (P70180) of - 20%
•
Adapt the maximum motor speed (P322.00)
and the error threshold (P350.01)
•
Check drive sizing
•
Check settings for the braking energy
management
Note: The warning will be reset if the thermal
load falls below the warning threshold (P707.08)
of - 20%
•
Deactivate start command and reset error
•
To exit the control mode, press the control
keypad key
|
+1 800 668 2268
Blocking
Reset
Times
Possible
0
Yes
0
Yes
0
Yes
0
Yes
5
Yes
0
Yes
0
Yes
0
Yes
1
Yes
0
Yes
5
Yes
1
Yes
0
Yes
0
Yes
0
Yes
|
18