2. Important Information
WARNING: The InnEnergy® device only switches the 'live' on and off. It
does not isolate the attached cooler. The cooler must be unplugged from the
InnEnergy® device before any maintenance work is carried out.
The operating voltage is limited to 207-250V ac. Do not use outside this range.
The maximum output current is 13A.
The InnEnergy® device is suitable for indoor use only.
To prevent fire or shock hazard, do not expose the InnEnergy® device to rain or
moisture.
To avoid electrical shock do not open the device.
No user serviceable parts inside.
Ensure that the cooler plug is inserted fully into the InnEnergy device. Also
Ensure that the InnEnergy device is inserted fully into the power socket.
The user should determine the applicability of this device for their equipment and
product range. DFx Technology Ltd. accepts no liability for loss, damage or injury
of any kind arising from the inappropriate use of this device.
The amount of energy saved is dependent upon the establishment's trading hours.
Individual savings will vary.
These instructions are suitable for use with InnEnergy devices manufactured after
01/10/09. Other instructions may superceed the advice given herewithin.
3. Specifications
•
RMS voltage 207-250V AC rms
•
RMS current 0.00 ~ 13.00 A rms
•
Active power: Typically 3,000 Watts
•
Apparent power 0 ~ 3750 VA
•
Line Frequency 50 Hz
•
Power Factor 0.00 ~ 1.00
•
Energy Quantity 0.00 ~ 99,999 kWh
•
kWh Hour 00:00 ~ 99,999
•
Clock: 24 Hour, Calendar, Leap Year and Daylight Saving
•
Dimensions: 130.0 mm (H) x 65.0 mm (W) x 85.0 mm (D)
•
Weight: 217g