Allied Telesis Rapier Series Manual de solución de problemas - Página 3
Navegue en línea o descargue pdf Manual de solución de problemas para Interruptor Allied Telesis Rapier Series. Allied Telesis Rapier Series 8 páginas. How to set up pppoe between a linux client and access concentrator
También para Allied Telesis Rapier Series: Solución de problemas (5 páginas), Nota de publicación (8 páginas), Cómo configurar (9 páginas), Cómo hacerlo (8 páginas)
If the interface is not activated, the reason could be one of the following:
1.
2.
Board
------------------------------------------------------------------------
Base
IC Module
Interface State
------------------------------------------------------------------------
eth0
port0
port1
port2
port3
BRI0
------------------------------------------------------------------------
3
The interface has been put into NT mode.
On the AT-AR041 and AT-AR042 multi-BRI NSM modules it is possible to put the ISDN
interface(s) into NT mode so that they can emulate a network switch interface. This can
be useful for bench testing network configurations. To see which mode the ISDN interface
is currently in, use the command:
show bri=n state
The first item in the output, Interface Type, will have either the value NT or the value TE.
If the ISDN interface is in TE mode then it is set up correctly.
If the ISDN interface is in NT mode it is set up incorrectly, and it is a matter of changing
a pair of jumpers on the circuit board to put the interface back into TE mode.
There is a physical fault in the router's ISDN interface circuitry.
The router is able to test its own interface. The steps to performing the self-test are:
a
Create a BRI loopback plug and insert it into the interface socket.
If the BRI interface under consideration is on an ICM card, it is not necessary to use a
loopback plug, as the interface is capable of internal loopback, and so does not need
external loopback.
b
At the command prompt, enter the command:
enable test int=brin
where n is the number of the BRI interface under consideration. Interfaces are
numbered from 0.
This initiates a 4-minute self-test.
c
Wait 4 minutes, until the router outputs a message to inform you that the self-test is
complete.
Then enter the command:
show test
which will output the test results as shown in the following figure.
ID
Bay Nick Name
47
3100
39
0
ICM-BRI1
Result
no test
no test
no test
no test
no test
complete
good
If the Result column shows the result to be good, then the BRI interface has no physical
faults (that the self-test can detect, anyway). If the result is anything other than good,
then the interface is faulty and you need to contact your distributor regarding a repair.
Part Name
NIQ-3100
EXP-0303
Type (minutes) Data( %OK ) Control
-
-
-
-
-
Rev
Serial number
M2-0
9774202
M1-2
8620690
Duration
Details
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
good(100.0)
-
-
-
-
-
-
-
-
-
-
-