CPS IAQPRO SmartAir Manual del usuario - Página 7

Navegue en línea o descargue pdf Manual del usuario para Instrumentos de medida CPS IAQPRO SmartAir. CPS IAQPRO SmartAir 9 páginas. Professional indoor air quality meter
También para CPS IAQPRO SmartAir: Manual del usuario (18 páginas), Manual de inicio rápido y resolución de problemas (8 páginas)

CPS IAQPRO SmartAir Manual del usuario
AIR QUALITY (Issues, Causes, Solutions) Cont'd
Indoor Air
Potential Causes
Quality Issues
Remove contaminants inside home or
VOC Contaminants
garage
The U.S. EPA reports
Improve ventilation inside home or garage
that on average, 60% of
Add garage ventilation fan to exhaust/create
High VOC Level
VOC's enter the home
negative pressure
through an attached
Seal garage/mud door from home
garage
Mechanical equipment
Inspect gas appliances and heaters for leaks
issues
Add or increase size of return registers in
Insufficient returns
bedrooms
High CO2 Level
Add ERV (Energy Recovery Ventilation) or
Inadequate ventilation
HRV (Heat Recovery Ventilation) to exchange
stale air with fresh air
Negative air pressure in
summer
Negative air pressure
High Or Low
in winter
Inspect windows, doors or other openings in
Building
the building envelope for air leaks
Positive air pressure in
Pressure
summer
Positive air pressure
in winter
In the summer, conden-
sation forms on ducts,
Ensure AC system is proper size (tons) and
air diffusers, walls or
High Or Low
functioning properly. Check ductwork or
ceilings
Dew Point
building envelope for leaks. Determine if
In the winter, conden-
insulation missing
sation forms inside
exterior walls
12
Recommended
Recommended Solutions
Indoor Levels
No federally enforce-
able limits, but 50 ~
325 ppb are thought
to be acceptable, but
recommended to not
exceed 500 ppb.
350-1,000 ppm
is typical level in
occupied spaces with
good air exchange.
Slightly positive
+.02-in. to +.03-in.
WC. can make a
huge difference in
building comfort and
efficiency.
OSHA recommends
24 to 60 °F (−4.5 to
15.5 °C)
+
APP SCREENS (IAQ PRO + CPS Link)
Indicates room temperature & humidity
being measured
Determine If your Temperature & Humidty are in the Comfort Zone
+
Trapezoid shape indicates Indoor Comfort Zone
as specified by ANSI/ASHRAE Standard 55
13