There are no field replaceable parts in an M6. The unit should be
returned to the factory for all repairs.
Build up of large amounts of contamination are to be avoided,
therefore periodic cleaning is recommended.
The condition of the bearings is important to the safety of the
explosion-proof housing. The bearing manufacturer's rated life
INTERNAL
GROUNDING LUG
7.19
[182.63]
DIA
EXTERNAL
GROUNDING LUG
3/4" NPT
2.75
PULSE GENERATOR
Type
Option Code
PPR
2.81
Imax= 160mA, Pmax= 4.48W Ea Output
Ex de IIC T4 (Tamb
to +80˚C)
CE 0539
Ex
II 2G
Cert No.
DEMKO 02 ATEX 131477X
WARNING: DO NOT OPEN IN A FLAMMABLE
ATMOSPHERE OR WHEN ENERGIZED
Tamb -20°C to +80°C standard, optional Tamb -40°C to +80°C available with
special option codes 001.
5 – IDENTIFICATION LABEL: SEE ABOVE
4 – DIMENSIONS IN PARENTHESIS ARE MILLIMETERS
3 – PILOT MOUNTING CONFORMS TO A NEMA 56C FACE
2 – ALL DIMENSIONS ARE APPROX.
1 – WEIGHT: 16 LBS. MAX.
NOTES:
*
"VDC" to be "5-18" or "5-24" or "12-24"
EU DECLARATION OF CONFORMITY: The Model M6 Encoder has been assessed and type tested against the following Harmonized
European Standards: EN 50081-1:1992, EN 50082-1:1998. The Model M6 has been found to be compliant with the requirements of EU
Directive 89/336/EEC provided that the following conditions are met: The electrical supply to the M6 must be within specified limits. The
electrical supply must offer suitable protection from voltage surges unless the application does not require such protection. On behalf of Avtron:
Stephen L D'Henin, Certification Manager, Epsilon Certification Service.
8901 E. PLEASANT VALLEY RD., INDEPENDENCE, OH 44131, U.S.A. • (216) 642-1230 • FAX (216) 642-6037 • www.avtronencoders.com
OUTLINE DRAWING
SHAFT
AA
3.77 [95.88]
OPTION
1
2
0.12 [3.05]
SHAFT OPTION 2 IS FOR USE
WITH OPTIONAL FOOT BRACKET
SHOWN BELOW
3/16 (4.763) SQ KEY (FURNISHED)
0.6250
DIA
0.6245
[15.8750]
DIA
[15.8623]
OPTION "T"
TERMINAL BLOCK
B31661
0539
5.02
Rev
Ser.No.
Date Mfg
[127.51]
VDC
0.82
[20.83]
IP66
These instructions have been reviewed and the product evaluated as suitable for our application.
Company Name
Authorized Company Representative
Title
INDUSTRIAL AUTOMATION, INC.
(see specifications) can be adversely affected by application
specific conditions. If the unit shows signs of bearing wear
indicated by noise or degradation of the electrical signal output, it
should be returned to the factory for repair.
DIM
AA
6.44 [163.63]
2.06 [52.33]
2.64 [67.06]
4.500
DIA
4.497
[114.300]
DIA
[114.224]
5.32
[135.13]
7.25
[184.15]
0.33 [8.38]
WITH ARMOURED CABLE GLAND
NOTE: CABLE GLAND Tamb (-60∞ C to +80∞ C)
2.51
[63.75]
0.58 [14.73]
0.15 [3.81]
3.685
+0.000
-0.030
4.505
114.427
[93.60
+.0
Ø
-.76
4.502
114.350
4.28
[108.71]
2.00
[50.80]
Features and specifications subject to change without notice.
Avtron standard warranty applies. All dimensions are in inches (mm) approx.
4.40 [111.76]
45∞
(REMOVE BLANKING ELEMENT
TO UTILIZE OPTIONAL 2nd OUTPUT)
3/8-16 UNC-2B THREAD
5.44 [138.23]
4 HOLES EQUALLY SPACED
ON A 5.875 [149.225] DIA B.C.
OPTION "W"
SEE NOTE 3
TERMINAL BLOCK
MUST BE DERATED FOR
TEMPERATURE RISE IN ENCODER.
OPTIONAL FOOT BRACKET
INCLUDES ALL HARDWARE NECESSARY
FOR MOUNTING PULSE GENERATOR AND
FOOT BRACKET TO MACHINE BASE.
FOR USE WITH SHAFT OPTION 2
Ø2.00
[50.80]
]
7.06
[179.32]
3.62
[92.08]
7.25
[184.15]