Dell PowerEdge 1600SC Manual de servicio - Página 6
Navegue en línea o descargue pdf Manual de servicio para Servidor Dell PowerEdge 1600SC. Dell PowerEdge 1600SC 7 páginas. Wake-on-lan (wol) support on dell servers
También para Dell PowerEdge 1600SC: Manual (15 páginas)
System Overview: Dell PowerEdge 1600SC Systems Service Manual
Video memory
Power
DC power supply (per power supply):
Wattage
Voltage
Heat dissipation
Output hold up time
Maximum inrush current
System battery
Physical
Height
Width
Depth
Weight
Environmental
Temperature:
Operating
Storage
Relative humidity:
Operating
Storage
Maximum vibration:
Operating
http://support.jp.dell.com/docs/systems/pe1600sc/en/sm/overview.htm (6 av 7)2004-12-10 10:45:50
8 MB
450 W
100–240 VAC, 50–60 Hz
2275 BTU/hr maximum
20 ms minimum
Under typical line conditions and
over the entire system ambient
operating range, the inrush
current may reach 55 A at 10
ms or less or 25 A at 150 ms or
less.
CR2032 3.0-V lithium coin cell
44.7 cm (17.6 inches)
21.8 cm (8.6 inches)
57.41 cm (22.6 inches)
33.11 kg (73 lb), maximum
configuration
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
20% to 80% (noncondensing)
5% to 95% (noncondensing)
0.25 G (half-sine wave) at a
sweep of 3 to 200 MHz for 15
minutes