Dell PowerEdge 1655MC Manual complementario - Página 15
Navegue en línea o descargue pdf Manual complementario para Servidor Dell PowerEdge 1655MC. Dell PowerEdge 1655MC 24 páginas. Removing a fan
También para Dell PowerEdge 1655MC: Manual de hardware (10 páginas), Manual de hardware (14 páginas)

NOTICE: Be careful not to bend any of the pins when removing the processor. Bending the pins
can permanently damage the processor.
Lift the processor out of the socket (see Figure 1-8) and place the processor on a flat
4
surface so that the pins are facing up.
Repeat step 1 through step 4 of this procedure for the second processor or the
5
terminator.
F i g u r e 1 - 8 .
R e m o v i n g a n d I n s t a l l i n g a P r o c e s s o r
pin 1
back of server
module
opening slide
slot
processor socket
Removing the Server Module Board
The server module board is secured by six retaining tabs and a securing clip on the end of
the board near the midplane board connector.
CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
flat-tip screw driver
closing slide
slot
front of server
module
Re plac ing the Se r ve r Mo dule Bo ard
1-11