Table 1. LCD Status Messages (continued)
Code
Test
E1716 Chipset
E1717 IERR
E1914 DRAC5 Conn
2 Cbl
E2122 Fatal Mem
Reset
I1915 Video Off
I1916 Video Off
in XX
NOTE:
For the full name of an abbreviation or acronym used in this table, see "Glossary"
in your Hardware Owner's Manual.
New SEL Sensor Messages
The following SEL sensor messages have been added to the systems
management software and remote access card software.
Table 2. Sensor Message Definitions
Sensor Number Message
0x26
Causes
The BIOS has determined
that there is a problem
with the chipset, but is
unable to determine its
origin.
CPU is faulty. Applicable
only for BIOS 1.1.9 and
BMC 2.27 and later.
DRAC5 cable is missing,
loose, or faulty.
System memory failed.
Local video is disabled.
Remote disabling of local
video currently in process.
PCIE Non Fatal
error
Corrective Actions
See "Getting Help" in your
Hardware Owner's Manual.
Either the CPU or system
board must be replaced. See
"Getting Help" in your
Hardware Owner's Manual.
Reseat the cable. If
problem persists, replace
the cable. See "Getting
Help" in your Hardware
Owner's Manual.
See "Troubleshooting
System Memory" in your
Hardware Owner's Manual.
Information only.
Information only.
Definition
A non-fatal error occurred. The system
will continue to operate normally.