POSSIBLE CAUSE
1
BURNER SHUTTING DOWN DURING OPERATION
A. Insuffi cient or excessive gas
pressure
B. Log placement
C. Flue area, fireplace, or
damper dirty from soot
D. Fireplace too small for unit
E. P i l o t f l a m e l i f t i n g o f f
thermocouple/generator
F. Pilot (remote compatible)
G. Blockages on burner
2
A. P i l o t f l a m e l i f t i n g o f f
thermocouple/generator
B. Electronic spark not lighting
pilot
C. Ignitor electrode wire loose
D. Gas supply off/manual
shutoff valve closed
E. Air in gas line
F. Pilot hood blocked
F. Dead batteries (electronic
pilots only)
3
A. Gas pressure
B. Propane tank running low
4
A. Burner orifi ce clogged
B. Top burner lights; bottom
burner has delayed ignition.
5
A. Gas leak
B. New home, new carpet, or
new paint

TROUBLESHOOTING

A1. Check gas pressure (check with local gas company).
A2. Other gas appliances may be on the same gas line, dropping gas pressure
to log set. Check pressures with everything operating to ensure adequate
pressure.
B. Reference the LOG PLACEMENT section in this manual for recommended
log positioning.
C. Clean around, above, and under damper thoroughly. Clean fi replace, removing
loose material, including soot and creosote.
D. Ensure minimum requirements are met. (See FIREPLACE SIZE
REQUIREMENT section in this owner's manual.)
E. Check gas pressure (see section A1).
F. Contact your dealer for instructions on replacement.
G. Vacuum any lava granules or material that may have fallen onto burner pipe
area.
PILOT WILL NOT LIGHT
A. Check gas pressure (check with local gas company).
B. Check to assure sparking when activated.
Note: You may need to turn or press ignitor several times to ignite pilot. See
LIGHTING INSTRUCTIONS for your control valve.
C. Check wiring and reconnect any loose wiring.
D. Turn on gas supply or open manual shutoff valve.
E. Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS until air is
removed.
F. Check for debris or dirt / Clean pilot
F. Replace batteries as needed.
LOW FLAME HEIGHT
A. Check gas pressure (check with local gas company).
B. Fill tank completely.
BURNER NOT BURNING EVENLY
A. Clean burner orifi ce.
B1. Check gas pressure. Can be caused by too small of a gas line (See ANSI
223.1/NFPA 54 Piping Guidelines).
B2. Low propane tank level. Vacuum burner tube for soot blockage and fi ll propane
tank.
ODORS
A. Shut off gas, if possible. Follow instructions on front page. Have a qualifi ed
professional installer or the gas company correct all leaks.
B. When these odors are drawn into the fi replace, this may cause objectionable
odors. Thoroughly ventilate the area before restarting your log set.
15