DIP Switch Settings
SW 1 DIP Switches
The DIP switches in the SW 1 DIP switch set described in the following table allow you to
set the operating mode of the line card. For information about the operating modes as
well as Smart MissingLink and MissingLink, refer to the relevant management software
user's guide.
Operating Mode
DIP 1
Link Test (default)
OFF
OFF
Smart MissingLink (SML)
OFF
ON
MissingLink (ML)
OFF
OFF
Manufacturing Default Settings
OFF
OFF
"X" means that the DIP switch position can be ON or OFF.
SW 2 DIP Switches
The DIP switches in the SW 2 DIP switch set described in the following table allow you to
configure the MDI/MDI-X feature on the twisted pair port..
Operating Mode
DIP 1
Auto MDI-X Enabled (default)
X
OFF
Auto MDI-X Disabled
X
ON
Manufacturing Default Settings
OFF
OFF
"X" means that the DIP switch position can be ON or OFF.
Twisted Pair Port Pinouts
The pinouts for the RJ-45 twisted pair port are shown in the following illustration.
8
8
1
1
The following table lists the RJ-45 pin signals when a twisted pair port is operating in the
MDI or MDI-X mode.
MDI Mode
Pin
Signal
Pin
1
TX+
1
2
TX-
2
3
RX+
3
6
RX-
6
Warranty Information
The AT-CV10x Series (AT-CV101, AT-CV102, and AT-CV102/x Series) line cards have a
limited warranty of five years. Go to www.alliedtelesis.com/warranty for the specific terms
and conditions of the warranty and for warranty registration.
Specifications
Physical, Environmental, and Electrical Ratings
Dimensions (H x W x L)
Weight
Operating Temperature
DIP 2
DIP 3
DIP 4
Storage Temperature
Operating Relative Humidity
OFF
X
Storage Relative Humidity
ON
X
Operating Altitude Range
ON
X
Predicted MTBF (Telcordia SR332)
OFF
OFF
Power Consumption
Optical Output Power (dBm)
DIP 2
DIP 3
DIP 4
Line Card
X
X
AT-CV101
X
X
AT-CV102
OFF
OFF
AT-CV102/1
AT-CV102/2
Receiver Power Sensitivity (dBm)
Line Card
AT-CV101
AT-CV102
AT-CV102/1
AT-CV102/2
Electrical Safety and Emissions Statements
This product meets the following standards when installed in compliant host equipment.
MDI-X Mode
Signal
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
RX+
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
RX-
radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
TX+
harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
TX-
operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
Emissions
Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Immunity
Electrical Safety
4
(2.2 cm x 7.3 cm x 13.0 cm)
.855 in. x 2.89 in. x 5.1 in.
0.27kg (0.60 lbs.)
0° C to 40° C (32° F to 104° F)
-25° C to 70° C (-13° F to 158° F)
5% to 90% (non-condensing)
5% to 95% (non-condensing)
Up to 3,048 m (10,000 ft.)
AT-CV101
1,020,000 hours
AT-CV102
890,000 hours
AT-CV102/1 1,020,000 hours
AT-CV102
1,020,000 hours
5.7 Watts
Minimum
Maximum
Wavelength
-20 dBm
-14 dBm
1310 nm
Dual ST
-20 dBm
-14 dBm
1310 nm
Dual SC
-15 dBm
-5 dBm
1310 nm
Dual SC
-15 dBm
0 dBm
1310 nm
Dual SC
Minimum
Maximum
-31 dBm
-11 dBm
-31 dBm
-11 dBm
-34 dBm
-3 dBm
-34 dBm
-3 dBm
U.S. Federal Communications Commission
Industry Canada
FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
EN55024
UL60950 (
UL
), EN60950 (TUV), CSA22.2 No. 950
c
us
Connector
Copyright © 2007 Allied Telesis, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied
Telesis, Inc.
5
6