ensto PXA53 Manual de instrucciones - Página 19

Navegue en línea o descargue pdf Manual de instrucciones para Accesorios ensto PXA53. ensto PXA53 20 páginas.

6. MAINTENANCE AND TROUBLE-SHOOTING
Should problems arise with the light fitting's operation, turn off the power for a few moments, then
recheck the operation. Check also that the lamps are fixed securely in their lamp holders. If this has
no effect, change the lamps. Check also the securing of the wires to the terminal block.
Always switch off the power before changing lamps! If the lamp has been changed while the
power is on, switch off the power for at least 30 seconds after changing the lamp.
If the PIR sencor fails to work though the power supply is on, switch off the power supply before
removing the PIR sensor from the light fitting and sending it for replacement.
7. CLEANING
The lens should be cleaned when necessary using a damp cloth. Do not use cleaning agents or
solvents as these may damage the lens surface!

8. TECHNICAL SPECIFICATIONS

Minimum mounting height 1.7 m.
Features a Passive Infra Red sensor unit (PIR).
Power supply 220 - 240 V, 50 / 60 Hz.
Detection area: horizontal 360°, vertical approx. 135°.
Switch off 1 - 30 min after movement ceases (TIME setting).
Sensitivity (within detection range) SENS and TIME setting.
LUX - position max (= infinity).
Dimmable electronic ballast: illumination level approx. 5% when continuously on (can be
changed to 20%). This rises to 100% when the PIR reacts to movement (can be changed to 80%).
Min illumination level can be disconnrct after 1 h, if there isn´t any movement, starting time
1 - 2 sec.
Max. external load: 400VA light fitting load.
Operating modes: automatic operation in dusk, test mode and lux setting mode.
19