Dell E03T Manual de introducción - Página 3

Navegue en línea o descargue pdf Manual de introducción para Almacenamiento Dell E03T. Dell E03T 17 páginas.

Setting Up the Storage System

Consider the following best practices when setting up an SC7020 series storage
system.
Dell recommends that you use a dedicated SAN network for data transmission
when using a Fibre Channel or iSCSI storage system.
Always configure redundant data paths to provide alternate paths to and from the
host server should one of the data paths become disabled.
Before connecting any cables between the storage system and host server or
expansion enclosure, physically label each port and connector.
Always follow proper power-up and power-down procedures when cycling power
across the network. Verify that critical network components are on separate
power circuits.
NOTE: This product is intended for restricted access locations, such as a
dedicated equipment room or equipment closet.
WARNING: If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room
ambient temperature. Therefore, consideration should be given to installing
the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.

Safety Warnings

Laser Radiation for Fibre Channel Storage Systems
Two person lift required
A fully configured SC7020 series storage system
weighs approximately 45 kg (100 lb). Use appropriate
lifting methods when installing the storage system.
CAUTION: Class I laser radiation when open, avoid exposure
to beam.
3