Dell EqualLogic FS7600 Manual del usuario del hardware - Página 13

Navegue en línea o descargue pdf Manual del usuario del hardware para Almacenamiento Dell EqualLogic FS7600. Dell EqualLogic FS7600 32 páginas. Appliances
También para Dell EqualLogic FS7600: Visión general (7 páginas), Manual de instalación y configuración (46 páginas)

Dell EqualLogic FS7600 Manual del usuario del hardware
Dell EqualLogic FS7600 Hardware Owner's Manual
Voltage
Battery Power Supply
Battery
Physical
Height
Width
Depth
Weight (maximum
configuration)
Weight (empty)
Environmental
Operating temperature
Storage temperature
Operational relative
humidity
Storage relative
humidity
Maximum operational
vibration
Maximum storage
vibration
Maximum operational
shock
Maximum storage
shock
Operating altitude
Storage altitude
Airborne Contaminant
Level Class
90 VAC to 264 VAC, autoranging, 47 Hz/63 Hz
This system is also designed to be connected to IT power systems with a phase to
phase voltage not exceeding 230 V.
12.8 V to 13.2 V, 4.8 Ah to 6 Ah, 63 Wh to 77 Wh
86.4 mm (3.4 in.)
481.5 mm (18.96 in.)—with rack flange
446.3 mm (17.6 in.)—without rack flange
813.0 mm (32.0 in.)—with bezel and handle
741.0 mm (29.2 in.)—without bezel and handle
30.5 kg (67 lb.)
12.86 kg (28.36 lb.)
Continuous operation: 5°C to 40°C (41°F to 104°F) with a maximum temperature
gradation of 20°C (68°F) per hour
–40°C to 60°C (–40°F to 140°F) with a maximum temperature gradation of 20°C per
hour
20% to 80% (non-condensing) with maximum humidity gradation of 10% per hour at
maximum wet bulb temperature of 29°C (89°F)
5% to 95% with a maximum humidity gradation of 10% per hour at a maximum wet
bulb temperature of 38°C (100°F)
0.26 G
(5 Hz – 350 Hz @ 0.0002G2/Hz) in operational orientation for 5 minutes
rms
1.88 G
with the following PSD profile (all 6 sides tested for 15 minutes each side)
rms
Frequency (Hz)
G2/Hz
10
0.13
20
0.13
70
0.004
130
0.004
165
0.0018
500
0.0018
31G half-sine shock +/-5% with pulse duration of 2.6 ms +/-10% in the operational
orientation
Square wave shock of 27G, at 235 inches/second (596.90 cm/second) velocity
change (all six sides tested)
-15.2 mto 3048 m (-50 to 10,000 feet)
For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550
feet.
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985
1 Basic Appliance Information
7