Dell EqualLogic PS4110E Manual de hardware - Página 46
Navegue en línea o descargue pdf Manual de hardware para Almacenamiento Dell EqualLogic PS4110E. Dell EqualLogic PS4110E 50 páginas. Equallogic ps series iscsi storage arrays with microsoft windows server failover clusters
Problem
The storage array firmware upgrade
process using Telnet, exits without
allowing you to enter y to the
following message:
Do you want to proceed
(y/n)[n]:
While running the Cluster Validation
Wizard, the Validate IP Configuration
test detects that two iSCSI NICs are
on the same subnet and a warning is
displayed.
46
Probable Cause
The Telnet program sends an extra
line after you press <Enter>
The two iSCSI NICs are configured in
the same subnet by design.
Corrective Action
User serial connection for the array
firmware upgrade.
To clear the extra linefeed in
Windows Telnet:
1. Enter ^](control, right bracket).
2. In the Microsoft Telnet prompt,
type unset crlf.
3. Press <Enter> to return to
Telnet.
No action required.