Dell PowerVault MD3200i Series Manual de instalación - Página 17

Navegue en línea o descargue pdf Manual de instalación para Almacenamiento Dell PowerVault MD3200i Series. Dell PowerVault MD3200i Series 18 páginas. Storage arrays
También para Dell PowerVault MD3200i Series: Manual de implantación (41 páginas), Manual de actualización (32 páginas), Instrucciones de instalación de la estantería (2 páginas), Manual del usuario (46 páginas), Matriz de apoyo (12 páginas), Información actualizada (1 páginas), Matriz de apoyo (11 páginas), Matriz de apoyo (17 páginas), Manual técnico (38 páginas), Libro Blanco (22 páginas), Manual (16 páginas)

Dell PowerVault MD3200i Series Manual de instalación
Table 4-1. Common Issues and Resolutions
Issue
On SUSE Linux Enterprise Server
platform, the CLI commands from
Pegasus/bin directory (like cimcli,
cimserver) fails and the following error is
displayed:
Error while loading shared
libraries: libpegclient.so.1:
cannot open shared object
file: No such file or
directory
On SUSE Linux Enterprise Server, the
CIM server fails to start during
installation and the following error is
displayed:
Unable to start CIMServer.
CIMServer is already running.
CIMServer start failed.
(continued)
Recommended Action
Set the environment variables
LD_LIBRARY_PATH and
PEGASUS_HOME in the command line
shell to point to the Pegasus libraries and
Pegasus directory respectively.
For example, with default installation of
SMI-S Provider, you can set this variable
as follows:
set LD_LIBRARY_PATH=
/opt/dell/pegasus/lib
set PEGASUS_HOME=
/opt/dell/pegasus
This issue occurs during the previous
uninstall step of the provider; the
CIMServer could not be stopped
successfully.
This happens when the
PEGASUS_HOME and
LD_LIBRARY_PATH environment
variables are not set correctly during the
uninstall process. To start the CIM server
after the install, set the
LD_LIBRARY_PATH and
PEGASUS_HOME environment
variables, then stop and start the CIM
server.
Troubleshooting the SMI-S Provider
17