Dell PowerVault NX3200 Manual de solución de problemas - Página 10

Navegue en línea o descargue pdf Manual de solución de problemas para Almacenamiento Dell PowerVault NX3200. Dell PowerVault NX3200 17 páginas. Network-attached storage
También para Dell PowerVault NX3200: Manual del administrador (50 páginas), Puesta en marcha (2 páginas), Manual de introducción (9 páginas), Especificaciones (2 páginas)

Dell PowerVault NX3200 Manual de solución de problemas
Table 1. Installation Issues
Issue
Error: -5007.
Error occurred
while
attempting to
create OS
volume.
Errors due to
third-party tools
and utilities.
The package provided
is not a NAS
appliance software.
10
Troubleshooting Guide
(continued)
Description
A pre-existing virtual disk
with LUN ID 0 that is
not being used for the
NAS operating system
has been encountered.
The package provided for
the PowerVault NAS

Initial Configuration

Wizard is not a
recognized NAS
appliance software.
Workaround / Solution
The operating system on the
PowerVault NAS system must be
on virtual disk 0.
To workaround this issue, the
current virtual disk with LUN ID 0
must be deleted for the operating
system reinstallation to proceed.
Backup all data on virtual disk 0
1
if possible.
Reboot your system and boot
2
into the PERC controller BIOS
during POST. For more
information about booting into
the PERC controller BIOS, see
PERC user's guide at
support.dell.com/manuals.
Delete the virtual disk with LUN
3
ID 0.
Reboot the PowerVault NAS
4
using the operating system
reinstallation media or DVD.
To workaround this issue, follow
the instructions in the error
message. If the error cannot be
resolved, contact Dell.
For more information, see "Getting
Help" in the Hardware Owner's
Manual at
support.dell.com/manuals.
Ensure that the package
downloaded from
support.dell.com is compatible
with your system.