PS6000 Hardware Maintenance
Note: If you need to reverse the cable strain relief wire for your power cable
configuration, press the wire ends together as shown in Figure 4-5 to
disengage the wire from the power plug socket. Reverse the wire and re-
attach it to the socket.
Figure 4-5: Using the Cable Strain Relief
7. Turn on power to the power supply and cooling module. Initialization
generally takes from one to ten seconds. When initialization completes, the
power LED is green and an event message states that fans have returned to
their normal speed.
8. To make sure the new module is working, make sure there are no red LEDs.
Also, examine the GUI Member Enclosure window or run the CLI
select show enclosure
Caution:
After installing a power supply and cooling module, wait until the
new module initializes before removing the other module. New
module initialization can take from one to ten seconds. When
complete, the power LED is green and an event message states that
fans have returned to their normal speed.
Maintaining Power Supply Modules
command. Make sure the status is
member
.
on
4–5