Dell EMC PowerSwitch S4200-ON Series Manual de instalación - Página 17
Navegue en línea o descargue pdf Manual de instalación para Interruptor Dell EMC PowerSwitch S4200-ON Series. Dell EMC PowerSwitch S4200-ON Series 19 páginas.
This section lists the S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 113°F—45°C.
CAUTION:
Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced.
Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's
instructions.
NOTE:
For RoHS information, see
Topics:
•
Chassis physical design
Chassis physical design
Table 1. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Table 2. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Restricted Material
Compliance.
Specifications
1.72 inches (44 mm)
17.1 inches (434 mm)
18.2 inches (462 mm)
PSU/fan tray handle: 1.57 inches (40 mm)
22 lbs (2* PSUs)
9.98 kg (2* PSUs)
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Specifications
0°C to 45°C (32°F to 113°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
–40° to 70°C (–40° to 158°F )
5% to 95%, non-condensing
Specifications
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
4
Specifications
17